THE SLIP RESISTANCE INSPECTION SERVICES DIARIES

The Slip Resistance Inspection Services Diaries

The Slip Resistance Inspection Services Diaries

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it concerns guaranteeing security in industrial, commercial, and residential spaces, slip resistance testing is an important aspect. At ATTAR (Advanced Technology Testing & Research), we specialize in floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help organizations and property owners reduce threats and abide by safety standards.

With cutting edge devices such as the pendulum slip test maker and moisture meter for concrete, we supply accurate and independent slip testing services across Australia. Our knowledge covers ASTM F2170 compliance, R Ranking evaluations, P Ranking tiles, and more, ensuring your floors meet the highest safety criteria.

Why Slip Resistance Testing is Vital


Slips and falls are amongst the leading reasons for office and public injuries. Correct slip testing assists determine harmful surface areas before mishaps take place. Whether you need damp pendulum test evaluations or pendulum test for slip resistance, ATTAR delivers precise outcomes to improve safety.

Key Services Provided by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Score and P Score tiles assessments.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test using sophisticated moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Ensures visibility for visually impaired individuals.
- Complies with Australian accessibility requirements.

4. On-Site & Laboratory Testing

- Slip test machine for accurate on-site examinations.
- Wet pendulum test for damp surface area slip resistance.

Comprehending Slip Resistance Scores: R Score vs. P Score


When carrying out slip resistance testing, two key classifications are used:.

- R Ranking (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently used in Europe.

- P Score (Pendulum Test - AS 4586)
Assesses dynamic friction utilizing a pendulum test slip resistance device, commonly adopted in Australia.

ATTAR provides independent slip testing to determine whether your floor covering satisfies the required pendulum rating tiles requirements.

The Significance of Concrete Moisture Testing


Excess moisture in concrete slabs can result in flooring failures, mold growth, and adhesive deterioration. Our concrete moisture testing services include:.

> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to ensure ideal conditions for floor installations.

By detecting moisture concerns early, we help prevent pricey repair work and ensure long-lasting floor covering efficiency.

Luminance Contrast for Ease Of Access Compliance


Appropriate luminance contrast is essential for aesthetically impaired people to navigate spaces securely. ATTAR examines:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile signs.

Our evaluations ensure compliance with Australian Special needs Standards (AS 1428.1).

Why Select ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Fast & Trusted Reporting.

For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Common Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, restaurants, and workplaces require safe flooring to check here prevent consumer and worker injuries. Our pendulum slip test makes sure compliance with safety guidelines.

2. Industrial & Warehouse Facilities

High-traffic commercial environments need resilient, slip-resistant flooring. ATTAR's slip testing services assist maintain office safety.

3. Health Care & Aged Care Facilities

Health centers and assisted living home need to reduce slip threats. Our luminance contrast and slip resistance testing ensure safe movement for clients and staff.

4. Public Facilities

Paths, train stations, and government structures need independent slip testing to meet availability and security standards.

How ATTAR Performs Slip Resistance Testing


Step 1: Surface Evaluation

We examine flooring products and conditions (dry, damp, or contaminated).

Action 2: Pendulum Slip Test (AS 4663)

Utilizing a slip test machine, we measure the vibrant coefficient of friction (DCOF).

Action 3: Wet Pendulum Test

Simulates slippery conditions to evaluate real-world slip threats.

Step 4: Reporting & Compliance Accreditation

Detailed reports with R Score or P Score tiles classifications.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance technique includes a swinging arm with a rubber slider that simulates a foot's movement. The test measures:.

- Slip Prospective Value (SPV).
- Pendulum ranking tiles category (P0 to P5).

Higher rankings (P4/P5) indicate better slip resistance.

Moisture Testing for Concrete Floors: Preventing Failures


Moisture-related floor covering failures can be expensive. ATTAR's concrete slab moisture testing consists of:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete check.
- Slab moisture test data analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.

Ensure your property meets safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By picking ATTAR, you buy independent slip testing services, pendulum test slip resistance accuracy, and long-term floor safety services. Let us assist you create much safer, certified, and moisture-resistant environments.

Report this page